isofit.configs.sections.instrument_config
- class InstrumentUnknowns(sub_configdic=None)[source]
Bases:
BaseConfigSection
Instrument Unknowns configuration.
- class InstrumentConfig(sub_configdic=None)[source]
Bases:
BaseConfigSection
Instrument configuration.
- integrations
Number of integrations comprising the measurement. Noise diminishes with the square root of this number. Applicable in concert with parametric_noise_file or pushbroom_noise_file
- SNR
We have several ways to define the instrument noise. The simplest model is based on a single uniform SNR number that is signal-independnet and applied uniformly to all wavelengths
- Type:
- parametric_noise_file
We have several ways to define the instrument noise. The second option is a parametric, signal- and wavelength- dependent noise function. This is given by a four-column ASCII Text file. Rows represent, respectively, the reference wavelength, and coefficients A, B, and C that define the noise-equivalent radiance via NeDL = A * sqrt(B+L) + C For the actual radiance L.
- Type:
- pushbroom_noise_file
We have several ways to define the instrument noise. The third option is a full pushbroom noise model that specifies noise columns and covariances independently for each cross-track location via an ENVI-format binary data file.
- Type: